Condulet Form 5 Conduit Outlet Bodies

Form 5 malleable iron conduit bodies, covers and gaskets from Eaton's Crouse-Hinds Division are used in conduit systems to act as pull outlets for conductors being installed, provide openings for making splices and taps in conductors, make 90 degree bends in conduit runs, and provide access to conductors for maintenance and future system changes.

Form 5 conduit bodies are manufactured in trade sizes 1/2" to 4", and are interchangeable with Appleton Form 35 conduit bodies.   They are also available with a hot dip galvanized finish for added corrosion protection against road salt and other harsh environmental factors.

LB50M HDG ½” 4.5 10 71 N/ALB75M HDG ¾” 7.5 10 97 3 #6 AWGLB100M HDG 1” 12.5 10 143 3 #4 XHHWLB125M HDG* 1¼” 32.0 5 287 3 #2 XHHWLB150M HDG* 1½” 35.3 5 331 3 #1/0 XHHWLB200M HDG* 2” 73.0 1 534 3 #4/0 XHHWLB250M HDG* 2½” 142.0 1 1105 3 #300MCM XHHWLB300M HDG* 3” 173.0 1 1160 3 #400MCM XHHWLB350M HDG* 3½” 292.0 1 1989 3 #500MCM XHHWLB400M HDG* 4” 324.0 1 2099 3 #500MCM XHHW *1¼” - 4” LB and C bodies supplied with built-in rollers to facilitate wire pulling.Type LLCat. # SizeInternal vol. in cu. in.Unit qty.Wt. lbs. per 100Max. no. of conductorsLL50M HDG ½” 4.5 10 76 N/ALL75M HDG ¾” 7.5 10 95 3 #6 AWGLL100M HDG 1” 12.5 10 138 3 #4 XHHWLL125M HDG 1¼” 32.0 5 309 3 #2 XHHWLL150M HDG 1½” 33.0 5 332 3 #2 XHHWLL200M HDG 2” 68.0 1 497 3 #4/0 XHHWLL250M HDG 2½” 142.0 1 1105 3 #300MCM XHHWLL300M HDG 3” 173.0 1 1437 3 #350MCM XHHWLL350M HDG 3½” 292.0 1 2321 3 #350MCM XHHWLL400M HDG 4” 324.0 1 2431 3 #350MCM XHHWType C Cat. # SizeInternal vol. in cu. in.Unit qty.Wt. lbs. per 100Max. no. of conductorsC50M HDG ½” 4.5 10 98 N/AC75M HDG ¾” 7.5 10 118 3 #6 AWGC100M HDG 1” 12.5 10 170 3 #4 XHHWC125M HDG* 1¼” 35.0 5 309 3 #2 XHHWC150M HDG* 1½” 35.3 5 368 3 #1/0 XHHWC200M HDG* 2” 75.0 1 552 3 #4/0 XHHWC250M HDG* 2½” 153.0 1 1216 3 #300MCM XHHWC300M HDG* 3” 181.0 1 1437 3 #300MCM XHHWC350M HDG* 3½” 290.0 1 2210 3 #350MCM XHHWC400M HDG* 4” 320.0 1 2321 3 #350MCM XHHW *1¼” - 4” LB and C bodies supplied with built-in rollers to facilitate wire pulling.Type LRCat. # SizeInternal vol. in cu. in.Unit qty.Wt. lbs. per 100Max. no. of conductorsLR50M HDG ½” 4.5 10 71 N/ALR75M HDG ¾” 7.5 10 100 3 #6 AWGLR100M HDG 1” 12.5 10 157 3 #4 XHHWLR125M HDG 1¼” 32.0 5 332 3 #2 XHHWLR150M HDG 1½” 35.3 5 345 3 #2 XHHWLR200M HDG 2” 68.0 1 626 3 #4/0 XHHWLR250M HDG 2½” 142.0 1 1105 3 #300MCM XHHWLR300M HDG 3” 173.0 1 1437 3 #350MCM XHHWLR350M HDG 3½” 292.0 1 2321 3 #350MCM XHHWLR400M HDG 4” 324.0 1 2500 3 #350MCM XHHWType TCat. # SizeInternal vol. in cu. in.Unit qty.Wt. lbs. per 100Max. no. of conductorsT50M HDG ½” 6.0 10 111 N/AT75M HDG ¾” 9.5 10 137 3 #6 AWGT100M HDG 1” 15.0 10 196 3 #4 XHHWT125M HDG 1¼” 33.0 5 332 3 #2 XHHWT150M HDG 1½” 36.0 5 368 3 #1 XHHWT200M HDG 2” 76.0 1 663 3 #2/0 XHHWT250M HDG 2½” 142.0 1 1271 3 #300MCM XHHWT300M HDG 3” 173.0 1 1547 3 #300MCM XHHWT350M HDG 3½” 292.0 1 2542 3 #350MCM XHHWT400M HDG 4” 324.0 1 2542 3 #350MCM XHHWForm 55 Eaton’s Crouse-Hinds series Hot dip galvanized products Type TBCat. # SizeInternal vol. in cu. in.Unit qty.Wt. lbs. per 100Max. no. of conductorsTB50M HDG ½” 6.0 10 88 N/ATB75M HDG ¾” 9.5 10 120 3 #6 AWGTB100M HDG 1” 15.0 10 197 3 #6 AWGTB125M HDG 1¼” 33.0 5 342 3 #6 AWGTB150M HDG 1½” 36.0 5 420 3 #4 XHHWTB200M HDG 2” 76.0 1 691 3 #1/0 XHHWType XCat. # SizeInternal vol. in cu. in.Unit qty.Wt. lbs. per 100Max. no. of conductorsX50M HDG ½” 6.0 10 139 N/AX75M HDG ¾” 9.5 10 172 3 #6 AWGX100M HDG 1” 15.0 10 247 3 #4 XHHWX125M HDG 1¼” 33.0 5 416 3 #2 XHHWX150M HDG 1½” 36.0 5 463 3 #1/0 XHHWX200M HDG 2” 76.0 1 833 3 #2/0 XHHWCast iron coversCat. # Size Unit qty.Wt. lbs. per 100K50CM HDG ½” 50 23K75CM HDG ¾” 50 31K100CM HDG 1” 25 41K125CM HDG 1¼” and 1½” 20 91K200CM HDG 2” 5 208K250CM HDG 2½” and 3” 5 358K350CM HDG 3½” and 4” 5 550Neoprene gaskets – perforated centerCat. # Size Unit qty.Wt. lbs. per 100GK50N ½” 100 2.0GK75N ¾” 100 2.0GK100N 1” 50 2.9GK125N 1¼” and 1½” 25 5.0GK200N 2” 25 8.0GK250N 2½” and 3” 25 16.0GK350N 3½” and 4” 25 26.4Integral gasket cover – sheet steelCat. # Size Unit qty.Wt. lbs. per 100K50SG ½” 50 14K75SG ¾” 50 16K100SG 1” 25 46K125SG 1¼” and 1½” 20 62K200SG 2” 5 70K250SG 2½” and 3” 5 190K350SG 3½” and 4” 5 340Sheet steel coversCat. # Size Unit qty.Wt. lbs. per 100K50S ½” 50 9K75S ¾” 50 13K100S 1” 25 19K125S 1¼” and 1½” 20 31K200S 2” 5 50K250S 2½” and 3” 5 94K350S 3½” and 4” 5 1381” BC3 HDG CG1¼” BC4 HDG CG1½” BC5 HDG WR CG2” BC6 HDG WR CG2½” BC7 HDG WR CG3” BC8 HDG WR CG3½” BC9 HDG WR CG4” BC10 HDG WR CGBUBHub size Cat. #1” BUB3 HDG CG1¼” BUB4 HDG CG1½” BUB5 HDG CG2” BUB6 HDG CG2½” BUB7 HDG CG3” BUB8 HDG CG3½” BUB9 HDG CG4” BUB10 HDG CGBUBXL (extra large) with cover and gasket Hub size Cat. #2” BUBXL6 HDG3” BUBXL8 HDGBLB*Hub size Cat. #1” BLB3 HDG CG1¼” BLB4 HDG CG1½” BLB5 HDG WR CG2” BLB6 HDG WR CG2½” BLB7 HDG WR CG3” BLB8 HDG WR CG3½” BLB9 HDG WR CG4” BLB10 HDG WR CGBT Hub size Cat. #1” BT3 HDG CG1¼” BT4 HDG CG1½” BT5 HDG CG2” BT6 HDG CG2½” BT7 HDG CG3” BT8 HDG CG3½” BT9 HDG CG4” BT10 HDG CGBlank replacement covers Feraloy iron alloy (all B series moguls except BUBXL) SizeCat. # With round neoprene gasket1” or 1¼” BG48 HDG1½” or 2” BG68 HDG2½” or 3” BG88 HDG3½” or 4” BG98 HDG190M HDG ½” 25 23191 HDG ¾” 25 35192 HDG 1” 10 60193 HDG 1¼” 5 91194 HDG 1½” 5 167195 HDG 2” 5 215196 HDG 2½” 2 430197 HDG 3” 1 463198 HDG 3½ ” 1 655199 HDG 4” 1 800188 HDG* 5” 1 1200189 HDG* 6” 1 2100*Not UL listed.Clampback/spacersCat. # Size Unit qty. Wt. lbs. per 100CB1 HDG ½” 25 8CB2 HDG ¾” 25 10CB3 HDG 1” 25 12CB4 HDG 1¼” 25 21CB5 HDG 1½” 25 42CB6 HDG 2” 10 40CB7 HDG 2½” 10 49CB8 HDG 3” 10 62CB9 HDG 3½” 10 91CB10 HDG 4” 10 110CB11 HDG* 5” 5 135CB12 HDG* 6” 5 225*Not UL listed.ClampsCat. # Size Unit qty. Wt. lbs. per 100510 HDG ½” 100 6511 HDG ¾” 50 8512 HDG 1” 50 13513 HDG 1¼” 25 20514 HDG 1½” 20 30515 HDG 2” 10 64516 HDG† 2½” 5 104517 HDG† 3” 2 120518 HDG† 3½” 2 150519 HDG† 4” 2 220520 HDG* 5” 1 380521 HDG* 6” 1 690*Not UL listed.Also for use with thin wall (EMT) conduit.Three-piece conduit couplings – hot dip galvanized malleable ironApplications:Used to join two lengths of threaded conduit; couples conduit when conduit cannot be turnedStandard material:Malleable ironStandard finish:Hot dip galvanizedMalleable iron (concrete tight)UL File No. E-19189Clampbacks/spacers – hot dip galvanized ironApplications:To provide space between conduit and mounting surfaceUL File No. E-184283Clamps – hot dip galvanized ironApplications:To support rigid conduit and IMC to mounting surfaceUL File No. E-18428310 Eaton’s Crouse-Hinds series Hot dip galvanized productsConduit hubsConduit clamps – right angle type – hot dip galvanized ironApplications:Right angle – to attach the conduit run at a 90° angle to a beam or structural memberParallel type – to attach the conduit run parallel to a beam or structural memberConduit clamps Cat. # Size Unit qty. Wt. lbs. per 100RAC50HD ½” 30 37RAC75HD ¾” 50 40RAC100HD 1” 60 42RAC125HD 1¼” 75 49RAC150HD 1½” 80 54RAC200HD 2” 100 71RAC250HD 2 ½” 125 95RAC300HD 3” 165 107RAC350HD 3½” 200 120RAC400HD 4” 330 131Conduit hubs – mechanically galvanized malleable ironApplications:Ideal for terminating electrical conduit through the walls of enclosuresDesigned for use indoors or outdoors with rigid conduit and IMC, specific applications include food processing plants, distilleries, breweries, sewage disposal plants, chemical plants, paper processing mills and refineriesFeatures:Male thread typeTapered female thread for rigid conduit and IMCRecessed o-ring gasket assures raintight and secure environmental connectionsInsulated throat provides smooth pulling surfaceLocking screw on the nut doubles as a grounding screw for added safetyComplete size range from ½” to 6”Hubs fit standard knockouts; no special tools requiredConduit hubs Cat. # Size Unit qty. Wt. lbs. per 100MHUB1 HDG ½” 25 18MHUB2 HDG ¾” 25 25MHUB3 HDG 1” 5 50MHUB4 HDG 1¼” 5 25MHUB5 HDG 1½” 2 20MHUB6 HDG 2” 1 10MHUB7 HDG 2½” 1 10MHUB8 HDG 3” 1 5MHUB9 HDG 3½ ” 1 5MHUB10 HDG 4” 1 2MHUB11 HDG 5” 1 1MHUB12 HDG 6” 1 1 Class I, Division 2Class II, Divisions 1 & 2Class III, Divisions 1 & 2UL Standard 514BUL Listed – Certified by UL to CSA Standard C22.2 No. 18NEMA: FB-1Suitable for wet locationsStandard material:Malleable ironStandard finish:Mechanically galvanizedCertifications and compliances:Three-piece couplings, clampbacks & clamps 11 Eaton’s Crouse-Hinds series Hot dip galvanized products Cat. # Description Unit qty.Wt. lbs. per 100FBCM1 HDG Malleable iron flat blank cover 25 56SWCM1 HDG Malleable iron switch cover 25 63RCM1 HDG Malleable iron duplex receptacle cover 25 55Cat. # SizeUnit qty.Wt. lbs. per 100FDM1 HDG ½” 2 278FDM2 HDG ¾” 2 273FDM3 HDG 1” 2 284Cat. # SizeUnit qty.Wt. lbs. per 100FDCM1 HDG ½” 2 313FDCM2 HDG ¾” 2 294FDCM3 HDG 1” 2 306FD boxes & coversFD dimensionsØ .302.233.251.88 2.87FS2.13 5.30FD2.862.651.12FS 2.13FD2.861.12 2.87 6.105.30 Ø .30FD Covers – malleableFBCM1 HDG SWCM1 HDG RCM1 HDGApplications:Cast device boxes are installed to:Accommodate wiring devicesAct as pull boxes for conductors in a conduit systemProvide openings to make splices and taps in conductorsUse indoors and outdoorsUse in applications where boxes may be subjected to rough useFeatures:Green ground screw is located on the flange of the box for easy ground wire termination and is standard on boxesSuitable for use in wet locations when used with gasket and flat blank coversMounting lugs standardTapered threaded hubs (NPT) with integral bushingAvailable as shallow (FS) or deep (FD) configurationAmple wiring room provided in either FS or FD configurationWide selection of surface or flush covers available in three materials (sheet malleable, steel, aluminum)Malleable iron construction provides high tensile strength for strong, dependable serviceCovers are individually bagged and supplied with screwsCertifications and compliances:cULuscCSAusStandard material:Malleable ironStandard finish:Hot dip galvanizedFD boxesFDC boxesFDM1 HDGFDCM1 HDGFDC dimensions12 Eaton’s Crouse-Hinds series Hot dip galvanized productsXJG Rigid/IMC expansion couplingsXJG Rigid/IMC expansion couplings provide flexible, water-tight connections that protect rigid and IMC conduit wiring systems from damage caused by movementApplications:XJG expansion couplings are used with rigid metal conduit and IMC:To couple together two (2) sections of conduit subject to longitudinal movementIn conduit runs to prevent damage to conduit supports such as in a building or on a bridgeIndoors or outdoors in long conduit runs to permit linear movement caused by thermal expansion and contractionIn conduit runs that cross structural jointsOn long conduit runs to prevent conduit from buckling and ensuing circuit failuresXJG Ordering Information:Certifications and Compliances:UL Standard: 514BCSA 22.2 No. 18 3-12NEMA FB1Wet locationsThird party certified as an effective grounding means (i.e. the path to ground is permanent and continuous) for two sections of conduit subject to expansion or contractionOptions:Available in copper-free aluminum ..................SA(Not available on 5” and 6” sizes)Available hot dipped galvanized (standard on 1-1/4” and above)........................................HDGAvailable with redundant bonding jumper for visible indication of bonding – order separately (BJ Series)†Conduit SizeMax. Conduit MovementXJGCat. #XJG - Alum.Cat. #Optional Bonding Jumper†A DiameterBLengthBonding Jumper Length1/2 4 XJG14 XJG14 SA BJ14 2.25” 7.00” 20”1/2 8 XJG18 XJG18 SA BJ18 2.25” 11.00” 30”3/4 4 XJG24 XJG24 SA BJ24 2.25” 7.00” 20”3/4 8 XJG28 XJG28 SA BJ28 2.25” 11.00” 30”1 4 XJG34 XJG34 SA BJ34 2.43” 7.38” 20”1 8 XJG38 XJG38 SA BJ38 2.43” 11.38” 30”1-1/4 4 XJG44 HDG BJ44 3.12” 7.56” 24”1-1/4 8 XJG48 HDG BJ48 3.12” 11.56” 30”1-1/2 4 XJG54 HDG XJG54 SA BJ54 3.62” 8.00” 24”1-1/2 8 XJG58 HDG XJG58 SA BJ58 3.62” 12.00” 30”2 4 XJG64 HDG XJG64 SA BJ64 4.38” 8.75” 24”2 8 XJG68 HDG XJG68 SA BJ68 4.38” 12.75” 30”2-1/2 4 XJG74 HDG BJ74 4.87” 10.00” 24”2-1/2 8 XJG78 HDG BJ78 4.87” 14.00” 36”3 4 XJG84 HDG XJG84 SA BJ84 5.37” 10.25” 30”3 8 XJG88 HDG XJG88 SA BJ88 5.37” 14.25” 36”3-1/2 4 XJG94 HDG BJ94 6.62” 10.00” 30”3-1/2 8 XJG98 HDG BJ98 6.62” 14.00” 36”4 4 XJG104 HDG XJG104 SA BJ104 6.62” 9.81” 30”4 8 XJG108 HDG XJG108 SA BJ108 6.62” 13.81” 36”5 8 XJ128 HDG‡ 7.64” 14.75” 6 8 XJ148 HDG‡ 9.56” 15.13” †XJG expansion couplings use a metallic bushing and ground springs to create a high integrity internal ground connection. External ground XD3 HDG* 3.63” 8.63”1-1/4 XD4 HDG 3.96” 8.75”1-1/2 XD5 HDG 4.19” 8.78”2 XD6 HDG 4.63” 9.16”2-1/2 XD7 HDG 5.69” 9.53”3 XD8 HDG 5.72” 10.13”3-1/2 XD9 HDG 6.22” 10.81”4 XD010 HDG 6.75” 11.88”5 XD012 HDG 7.75” 12.50”6 XD014 HDG 9.00” 13.50”XJGD34 8.63” 16.26” 3.63” 2.43”1-1/4 XJGD44 8.75” 16.54” 3.96” 3.12”1-1/2 XJGD54 8.78” 16.83” 4.19” 3.62”2 XJGD64 9.16” 19.31” 4.63” 4.38”2-1/2 XJGD74 9.53” 19.80” 5.69” 4.87”3 XJGD84 10.13” 20.47” 5.72” 5.37”3-1/2 XJGD94 10.81” 21.00” 6.22” 6.62”4 XJGD104 11.88” 21.97” 6.75” 6.62”

crouse-hinds-form5-catalog-page.pdf
crouse-hinds-hot-dip-galvanized-brochure.pdf
crouse-hinds-hot-dip-galvanized-form5-catalog-page.pdf


华微科技(天津)有限公司
QQ:35875214
联系地址:天津市华苑产业园区海泰大厦B座512
联系邮箱:mading@.huaweitianjin.com
联系电话:022-244288888
手机号码:18622336331